water treatment

 

 

Purified water

 

Q1Raw water pretreatment process.

AMechanical filtration, activated carbon, softener.

 

Q2The role of the plate heat exchanger.

APlate heat exchangers are used for sterilization of pretreatment systems.

 

Q3What is the conductivity of primary reverse osmosis effluent and secondary reverse osmosis effluent?

AUsually the conductivity of primary reverse osmosis effluent is lower than 10, and the conductivity of secondary reverse osmosis effluent is lower than 4.

 

Q4RO1500L/H, is this the input amount of sewage?

AUsually the output is written, not the input.

 

Q5Is water pretreatment required before both primary and secondary reverse osmosis?

AYes, water pretreatment is required before both primary reverse osmosis and secondary reverse osmosis.

 

Q6The difference between the semi-automatic control system and the fully automatic control system of the water treatment system.

AThe fully automatic control system has high performance, it can be controlled directly on the touch screen, and various indicators can be directly observed.

The semi-automatic control system is that the operator manually controls the valve.

1. Fully automatic startup:

(1). Before operation, it is necessary to ensure that the preparations for reverse osmosis have been completed, and the valves of the pretreatment system are in operation.

(2).Primary reverse osmosis: open the primary pressure regulating valve 450, open the fresh water valve and the concentrated water valve, turn on the power switch, set the booster pump, primary high pressure pump and dosing pump switch to automatic, and press the operation mode button Set to Auto and the unit starts automatically. Adjust the primary pressure regulating valve and concentrated water valve to make the flow rate reach the rated value.

(3). Secondary reverse osmosis: open the secondary pressure regulating valve at 450 degrees, open the fresh water valve and the concentrated water valve, turn on the power switch, set the secondary high pressure pump switch and the operation mode button to automatic, and the device will start automatically. Adjust the secondary pressure regulating valve and concentrated water valve to make the flow rate reach the rated value.

2. Manual boot:

(1).Primary reverse osmosis: open the primary pressure regulating valve at 450 degrees, open the fresh water valve and the concentrated water valve, turn on the power switch, and set the booster pump, primary high pressure pump, dosing pump switch and operation mode button to manual, The device starts automatically. Adjust the primary pressure regulating valve and concentrate valve to make the flow rate reach the rated value.

(2). Secondary reverse osmosis: open the secondary pressure regulating valve 450, open the fresh water valve and the concentrated water valve, turn on the power switch, set the secondary high pressure pump switch and the operation mode button to manual, and the device will start automatically. Adjust the secondary pressure regulating valve and concentrated water valve to make the flow rate reach the rated value.

3. Shutdown:

(1). The switches of operation mode, booster pump, primary high pressure pump, secondary high pressure pump and dosing pump point to stop, and the switch of power supply points to close.

(2). When the pretreatment control is manual, close the tap water inlet valve in front of the original water bucket.

(3). When the pretreatment control is automatic control, it is better to close the raw water inlet valve before the primary pump.

(4). If the pretreatment control is automatic control, the host power needs to be powered on for 24 hours, but the power switch on the panel can be turned off.

 

Q7What is the maximum size of water treatment equipment?

A80 tons.

 

Q8The process of primary water treatment. (Take the processing capacity of 500L per hour as an example)

ARaw water - pass the flocculant through raw water tank - sand filter - carbon filter - water softener - security filter - primary reverse osmosis.

 

Q9The process of secondary water treatment.

ARaw water - pass the flocculant through raw water tank - sand filter - carbon filter - water softener - security filter - primary reverse osmosis - secondary reverse osmosis - EDI - precision filtration - pure water tank - precision filtration - ultraviolet - feed pump.

 

Q10The role of Y-type filter in water treatment.

AY-type filters can prevent backflow and filter particles, and are generally used for industrial steam filtration and coarse filtration of water.

 

Q11When making shampoo and shower gel, what level of water treatment is recommended?

AUsually a primary reverse osmosis treatment is sufficient.

 

Q12The difference between reverse osmosis and water treatment.

AReverse osmosis is a part of water treatment.

 

Distilled water

 

Q1What is the storage temperature?

AThe storage temperature should be above 80°C or below 4°C.

 

Pure steam

 

Q1How many degrees of water can be used for injection?

AThe water can only be used for injection when it reaches 85°C.

 

Distribution system

 

Q1What are the components of the distribution system?

AStorage tanks, pumps, UV, heat exchangers.

Keyword:

Scan the QR code to read on your phone

Add:LTPM CHINA 2nd Floor,Dongxin Road and 5th Development Road ,Caizhai Industrial Zone,  Ruian City, Zhejing Province ,China

Tel:86-0577-65158955    Fax: 86-0577-65158944
Business Phone : 86-0577-65158955
E-mail:info@chinaleadtop.com

lead top

LeadTop Pharmaceutical Machinery Co., LTD  浙ICP备16043185号-1

LeadTop Pharmaceutical Machinery Co., LTD 浙ICP备20003428号-1